The ADMAG TI series AXG is ideal for industrial process lines like oil & gas/chemical/pulp & paper/food & beverage/metal & mining applications. With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, the AXG will increase user benefits while reducing total cost of ownership. | Yokogawa Electric Corporation
| AXG1A High Grade Transmitter | AXG4A Transmitter |
|---|---|
| Accuracy(Reading Value) | [Sensor Combination]- AXG: ± 0.3 %- AXW: ± 0.35 % |
| Size | [Sensor Combination]- AXG: 2.5 to 500 mm- AXW: 25 to 1800 mm |
| Use | [Transmitter]- General Purpose[Sensor Combination]- General Purpose- Explosion Protection- Hygienic- Submersible |
| Explosion Protection Use | [Sensor Combination]- AXG: IECEx, ATEX, USA (FM), Canada (FMc), Japan, Korea, Brazil (INMETRO), EAC- AXW: IECEx, ATEX, Korea, Brazil (INMETRO), EAC* Transmitter is usable only in the safety area. |
| Liner Material | [Sensor Combination]- AXG: Ceramics, PFA- AXW: PTFE, Polyurethane,Natural Soft Rubber,Natural Hard Rubber |
| Communication Protocols | HART 7, BRAIN |
| Signal Cable Length | 200 m |
| Main Function | - Easy Setup Wizard, Trend Graph Display Function- Data Logging Function (with microSD card)- Parameter Backup / Restore / Duplication Function (with microSD card)- Zero Adjustment- Display Test Function- Input/Output Test Function |
| Diagnostic Function | [Application Diagnostics]- Electrode Adhesion Detection- Sensor Empty Check- Wiring Connection Diagnosis- Flow Noise Diagnosis- Low Conductivity Diagnosis- Electrode Insulation Deterioration Diagnosis |
| Current Signal | Input: 1 ch (Active)Output: 2 ch (Active) |
| Pulse/Status Signal | Output: 2 ch (Active [With / Without Internal Resister] / Passive) |
| Status Signal | Input: 2 ch (Dry Contact)Output: 2 ch (Passive) |
| Alarm Signal | Output: 1 ch (Passive) |
| Multiple Languages | English, French, German, Italian, Spanish, Portuguese, Russian and Japanese. |
| Safety Integrity Level | - |
| Others | [AXG1A/AXG4A Transmitter, AXG Integral Type]- LCD with improved environmental resistance- Equipped with temperature input terminal for Density correction and Calolie calculation[AXG Flow sensor、AXG Integral Type]- Expand Lining flare diameter, improve Seal reliability- Compatible with high pressure specifications ASME Class 600- Selectable built-in grounding electrodes |
| Industries | Typical Line and Process |
| Chemical | - Polymerization process |
| Pulp & Paper | - Digester Circulation and Extraction Line- Blow Line- Bleach line- DIP |
| Food & Beverage | - Raw material blending process |
| Power | - LNG vaporizer |
| Iron & Steel | - Blast furnace tuyere |
| Items | Parameters |
| Displayable Data | Flow rate (%), PV, Velocity, Volume flow, Mass flow, Calorie, Analog Out 1/2, Totalizer 1/2/3 |
| Display Update Period | 0.2s, 0.4s, 1s, 2s, 4s, 8s |
| Recordable Data | PV, Velocity, Volume flow, Mass flow, Calorie, Flow Noise Value, Resistance Value of the electrode Adhesion Detection, Voltage of Electrodes (A, B), Peak Value of the Flow Rate Signal |
| Interval Time | 1s, 10s, 30s, 1m, 5m, 30m, 1h |
| Recordable Time | 10m, 30m, 1h, 3h, 12h, 24h, 72h, 240h |
| Built-in Verification | Simple diagnostic function that can be executed by a single device. |
| Standard/Enhanced Verification | More fundamental diagnostic function that utilizes FieldMate.In addition, Enhanced Verification allows for more accurate diagnostics. |
| Function | Description |
| Backup | Save parameter information to microSD card or memory with built-in LCD |
| Restore | Download parameter information to the same device (Device A to A) |
| Duplication | Download parameter information to other devices with the same model name and the same specification code (Device A to B) |
Заполните форму — ответим с актуальной ценой и сроком поставки в течение рабочего дня