Многофункциональный модуль полевой беспроводной сети FN310 с «Field Wireless Communication Module FN110» может подключаться к полевой беспроводной сети как полевое беспроводное устройство.
| Power Supply Specifications | Battery |
|---|---|
| Performance Specifications | Update Period |
| Battery Characteristics | [Protocol code: J]Battery pack with long life lithium-thionyl chloride batteries. At one-to-one connection, the typical battery life is 4 years when BootStrapTime*1*2of the HART device is 10 seconds or 1 year when BootStrapTime*1*2is 60 seconds, under the following conditions*3:- Ambient temperature: 23 ± 2 °C- Device role: IO mode- Update period: 10 minutes- LCD display: off*1: BootStrapTime is defined as the time from the power-on of the HART device until the reliable data is available.*2: For BootStrapTime, please contact the manufacturer of the connected HART device.*3: Environmental condition such as vibration and the type of connected HART device may affect the battery life.At 4-20 mA loop connection, the typical battery life is 8 years at 10 seconds update time or 5 years at 5 seconds update time in the following conditions.*4:- Ambient temperature: 23 ±2°C- Device role: IO mode- LCD display: off*4: Environmental condition such as viblratin may affect the battery life.[Protocol code: M]The typical battery life is 8 years under the flowingconditions*5:- Ambient temperature: 23 ± 2 °C- Device role: IO mode- Update period: 10 minutes- LCD display: off*5: Environmental condition such as vibration and the type of connected Modbus device may affect the battery life. |
| Functional Specifications | Input: |
| Power Supply | Power supply to the FN110 or FN120Supply voltage: 3.5 VSupply current: 50 mA[Protocol code: J]Power supply to the HART device* 1 * 2 *3Maximum supply voltage: 18 V (steady-state)Maximum supply current: 12 mA (steady-state)*1: HART devices operate at 4 mA current-fixed mode.*2: Before using, make sure the minimum operating voltage of the HART device is 16.5V or less with 0 ohm load..*3: Supply power when using VOUT terminal.[Protocol code: M]Power supply to the Modbus deviceSupply voltage: 3.5 VSupply current: 10 mA |
| Installation Environment | Ambient Temperature Limits |
| Regulatory Compliance Statements | CE Conformity |
| Canadian Safety Standards | CAN/CSA-C22.2 No.61010-1CAN/CSA-C22.2 No.94.1, CAN/CSA-C22.2 No.94.2IEC 60529 |
| Degrees of Protection | IP66, IP67 and Type 4X apply when the connector is properly tightened. |
| Explosion Protected Types | FM (United States or Canada), ATEX, IECEx Intrinsically safe Approval |
| Physical Specifications | Weight |
| Date | Remarks |
| 2024/12 | Important Notice for Safe Use of Products |