Wireless Specifications Communication protocol
Data rate 250 kbps
Frequency 2.400 - 2.4835 GHz license free ISM band
Radio security AES 128 bit codified
RF Transmitter power Max. 11.6 dBm (fixed)
Antenna +2 dBi Omni directionalDetachable Antenna type model (Amplifier housing code 8 or 9) can be used with a high-gain antenna1with an extension cable.

Технические характеристики

Wireless Specifications Communication protocol
Data rate 250 kbps
Frequency 2.400 - 2.4835 GHz license free ISM band
Radio security AES 128 bit codified
RF Transmitter power Max. 11.6 dBm (fixed)
Antenna +2 dBi Omni directionalDetachable Antenna type model (Amplifier housing code 8 or 9) can be used with a high-gain antenna1with an extension cable.
Standard Specifications Variety of sensor inputs
A/D accuracy Pt100: ±0.3°CType k: ±1°C
CJC accuracy (T/C only) ±0.5°C
Update period 1 sec to 60 min selectable
Battery life Typical battery life is 10 years at 10 seconds update time or 8 years at 5 seconds update time in the following conditions.2Detachable Antenna type model (Amplifier housing code 8 or 9)low power modeAmbient temperature: 23±2°CDevice role: IO modeLCD display: off
Physical Specifications Antenna
Weight 2.8kg(Without battery pack and mounting bracket)
Enclosure IP66/IP67, NEMA4X
Power supply Lithium thionyl chloride batteries (size D×2)
Battery Replacing Included zone 0
Certification Explosion protected type
EMC Conformity Standards EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3
R&TTE Conformity Standards ETSI EN 300 328, ETSI EN 301 489-1,ETSI EN 301 489-17, EN61010-1, EN61010-2-030, EN62311
Regulation Conformity of the Wireless Module • FCC Approval• IC Approval
Safety Requirement Standards EN61010-1, EN61010-2-030