Анализатор MG8G измеряет концентрацию кислорода парамагнитным методом. Модель предназначена для общепромышленного применения.
| Measurement object | Oxygen concentration in gaseous mixture |
|---|---|
| Measurement system | Paramagnetic system |
| Measurement range | 0-5 to 0-25 vol%O2, 3 range can be programmed |
| Analog output signal | 4 to 20 mA DC (load resistance; Max. 550Ω) |
| Contact output | Fail; 1 point, open or closed when error occures, user configurableMaintenance status; 1 point, closed during maintenanceRange answerback or Hi/Lo alarm; 2 points, normally de-energized |
| Contact input | Remote range switching, calibration start |
| Calibration method | Automatic calibration, semiautomatic calibration, manual calibration |
| Calibration gas | Zero gas; N2gasSpan gas; Dry air |
| Auxiliary gas pressure | N2gas, 180 kPa(Approx. 35 ml/min) |
| Sample gas condition | Gas flow; 200 ml/min ±10%Gas temperature; 0 to 50℃Humidity; No moisture condensation in the flow path or the sensor |
| Ambient temperature | -5 to 55℃ |
| Installation | Indoor, panel or wall mounting |
| Power supply | 100-115 V AC, 50/60 Hz or 200-240 V AC, 50/60 Hz |
| Repeatability | ±1% or less of F.S. |
| Linearity | ±1% or less of F.S. |
| Response time | 90% response within 3 sec(measured gas flow rate: 200 ml/min.) |
| Zero drift | ±1.5% or less of F.S./Week |
| Span drift | ±2% or less of F.S./Week |