Арт.: FLXA21

2-проводной двуканальный передатчик/анализатор FLXA21

Анализатор FLXA21 используется для непрерывных онлайн-измерений в промышленных установках, предлагая возможность измерения с одним или двумя датчиками, что делает их наиболее гибкими двупроводными анализаторами.

Цена по запросу  — уточняйте актуальную стоимость
Area Classification General PurposeClass I Div II (without the use of IS Barrier)Class I Div I (with the use of IS Barrier)
Enclosure Material Plastic (Polycarbonate)
Housing Rating IP66/ NEMA 4A/ CSA 3S
Power Supply 2-wire 24 VDC Loop Powered
Output Signal Bi-directional HART digital communication, superimposed on mA (4-20 mA) signalOptional FF (FOUNDATION Fieldbus) and PF (Profibus) communication
Intrinsically safe type ATEX, IECEx, FM, CSA and NEPSI, and nonincendive of FM and CSA.

Технические характеристики

Area Classification General PurposeClass I Div II (without the use of IS Barrier)Class I Div I (with the use of IS Barrier)
Enclosure Material Plastic (Polycarbonate)
Housing Rating IP66/ NEMA 4A/ CSA 3S
Power Supply 2-wire 24 VDC Loop Powered
Output Signal Bi-directional HART digital communication, superimposed on mA (4-20 mA) signalOptional FF (FOUNDATION Fieldbus) and PF (Profibus) communication
Intrinsically safe type ATEX, IECEx, FM, CSA and NEPSI, and nonincendive of FM and CSA.
Input Range Conductivity
Performance(The specifications are expressed with simulated inputs.) Conductivity
ORP Linearity: ±1 mV, Repeatability: ±1 mV, Accuracy: ±1 mV
Temperature Linearity: ±0.3 ºCRepeatability: ±0.1 ºCAccuracy: ±0.3 ºC
Input Specification The FLXA202 accepts output from membrane covered Dissolved Oxygen sensors. These sensors can be Galvanic type, where the sensor generates its own driving voltage or Polarographic type, where the sensor uses external driving voltage from the converter.The input range is 0 to 50 µA for Galvanic sensors and 0 to 1 µA for Polarographic sensors.For temperature compensation, the FLXA202 accepts Pt1000 (DO30 sensor) and NTC22k elements (OXYFERM and OXYGOLD sensors).
Display range Conductivity
Resistivity 0.005kΩ / K cm-1to 0.5MΩ /K cm-1: Accuracy: ±0.5%F.S.0.5MΩ / K cm-1to 1MΩ /K cm-1: Accuracy: ±1%F.S.
Performance (Accuracy)(The specifications are expressed with simulated inputs.) Conductivity
Temperature compensation NaCl table: ±1 %Matrix: ±3 %
Cable length max. 60 meters total length of fixed sensor cable + WF10(J) extension cable.Influence of cable can be adjusted by doing an AIR CAL with the cable connected to a dry cell.
Step response 90 % (< 2 decades) in 8 seconds
Measurement Range DO Sensors
DO30G Measurement range: 0 to 20 mg/l (ppm)Temperature: 0 to 40 ºC
Performance(Accuracy) (Performance in ppm mode) Linearity
Repeatability ±0.05 ppm or ±0.8% F.S., whichever is greater
Accuracy ±0.05 ppm or ±0.8% F.S., whichever is greater