Арт.: FLXA202

2-проводной двуканальный передатчик/анализатор FLXA202

Анализаторы серии FLEXA используются для непрерывных онлайн-измерений в промышленных установках, предлагая возможность измерения с одним или двумя датчиками, что делает их наиболее гибкими двупроводными анализаторами.

Цена по запросу  — уточняйте актуальную стоимость
Area Classification General PurposeClass I Div II (without the use of IS Barrier)Class I Div I (with the use of IS Barrier)
Enclosure Material Aluminum alloy die cast with epoxy coating (Standard offeringAluminum alloy die cast with urethane or high anti-corrosion coating (available upon request)
Housing Rating IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada)
Power Supply 2-wire 24VDC Loop Powered
Output Signal Bi-directional HART digital communication, superimposed on mA (4-20mA) signal
Intrinsically safe type ATEX, IECEx, FM, CSA and NEPSI, and nonincendive of FM and CSA

Технические характеристики

Area Classification General PurposeClass I Div II (without the use of IS Barrier)Class I Div I (with the use of IS Barrier)
Enclosure Material Aluminum alloy die cast with epoxy coating (Standard offeringAluminum alloy die cast with urethane or high anti-corrosion coating (available upon request)
Housing Rating IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada)
Power Supply 2-wire 24VDC Loop Powered
Output Signal Bi-directional HART digital communication, superimposed on mA (4-20mA) signal
Intrinsically safe type ATEX, IECEx, FM, CSA and NEPSI, and nonincendive of FM and CSA
Input Range Conductivity
Performance(The specifications are expressed with simulated inputs.) Conductivity
ORP Linearity: ±1 mV, Repeatability: ±1 mV, Accuracy: ±1 mV
Temperature Linearity: ±0.3 ºCRepeatability: ±0.1 ºCAccuracy: ±0.3 ºC
Input Specification The FLXA202 accepts output from membrane covered Dissolved Oxygen sensors. These sensors can be Galvanic type, where the sensor generates its own driving voltage or Polarographic type, where the sensor uses external driving voltage from the converter.The input range is 0 to 50 µA for Galvanic sensors and 0 to 1 µA for Polarographic sensors.For temperature compensation, the FLXA202 accepts Pt1000 (DO30 sensor) and NTC22k elements (OXYFERM and OXYGOLD sensors).
Display range Conductivity
Resistivity 0.005kΩ / K cm-1to 0.5MΩ /K cm-1: Accuracy: ±0.5%F.S.0.5MΩ / K cm-1to 1MΩ /K cm-1: Accuracy: ±1%F.S.
Performance(Accuracy)(The specifications are expressed with simulated inputs.) Conductivity
Temperature compensation NaCl table: ±1 %Matrix: ±3 %
Cable length max. 60 meters total length of fixed sensor cable + WF10(J) extension cable.Influence of cable can be adjusted by doing an AIR CAL with the cable connected to a dry cell.
Step response 90 % (< 2 decades) in 8 seconds
Measurement Range DO Sensors
DO30G Measurement range: 0 to 20 mg/l (ppm)Temperature: 0 to 40 ºC
Performance(Accuracy) (Performance in ppm mode) Linearity
Repeatability ±0.05 ppm or ±0.8% F.S., whichever is greater
Accuracy ±0.05 ppm or ±0.8% F.S., whichever is greater